Comparative evaluation of dentinal crack formation after root canal preparation using Pro Taper universal, Pro Taper Next and Pro Taper Gold

Dr. Harini Karunakaran Dr. Senthil Kumar K Dr. Anupama Ramachandran,Dr. Sadasiva K.

Abstract


Success of endodontic treatment depends on strict adherence to cleaning and shaping procedures.1 Root canal preparation technique involves complete disinfection and debridement of microorganisms from the canal, preparing and shaping the canal for placement of filling material but some amount of sound dentin also gets removed during the cleaning and shaping procedures.2 Excessive removal of sound dentin may weaken the tooth structure making it highly susceptible for perforation and dentinal crack formation under some               instances. Procedures like use of high concentration of            sodium hypochlorite,3 placement of intracanal post4 and some obturation techniques5 may aid in excess removal of dentin and ultimately leading to crack formation. However, it is the use of rotary instruments that have been identified as major cause for occurrence of dentinal cracks along root canal walls.6 The introduction of Niti rotary file systems made the cleaning and shaping procedures faster, efficient because of their  super elasticity7 and high cutting efficiency8. One of the major drawbacks of niti rotary systems is that it caused cracks along the root canal walls during preparation. The main           reason for formation of dentinal cracks is when tensile strength of root canal wall exceeds tensile strength of               dentin 9.10,11. These cracks can be extended as vertical root fracture (VRF) under constant functional load12  Even though there are several studies that evaluate the incidence of             dentinal crack formation after root canal preparation with different Niti systems 13,14,15,16,17,18,19 none of the studies    evaluated the incidence dentinal crack formation with the all the three Protaper systems. (ProTaper Universal (PTU),  ProTaper Next (PTN), ProTaper Gold (PTG)). The Null          hypothesis is there will be no difference in dentinal crack formation among all the three Protaper systems tested.

 


Full Text:

PDF

References


Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. Journal of endodontics. 2004 Aug 1;30(8):559-67.

Yoldas O, Yilmaz S, Atakan G, Kuden C, Kasan Z. Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file. Journal of endodontics. 2012 Feb 1;38(2):232-5.

Sim TP, Knowles JC, Ng YL, Shelton J, Gulabivala K. Effect of sodium hypochlorite on mechanical properties of dentine and tooth surface strain. International Endodontic Journal. 2001 Mar;34(2):120-32.

Kishen A, Kumar GV, Chen NN. Stress–strain response in human dentine: rethinking fracture predilection in postcore restored teeth. Dental Traumatology. 2004 Apr;20(2):90-100.

Onnink PA, Davis RD, Wayman BE. An in vitro comparison of incomplete root fractures associated with three obturation techniques. Journal of Endodontics. 1994 Jan 1;20(1):32-7.

Bier CA, Shemesh H, Tanomaru-Filho M, Wesselink PR, Wu MK. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation. Journal of Endodontics. 2009 Feb 1; 35(2):236-8.

Baumann MA. Nickel–titanium: options and challenges. Dental Clinics. 2004 Jan 1;48(1):55-67.

Schäfer E, Lau R. Comparison of cutting efficiency and instrumentation of curved canals with nickel-titanium and

stainless-steel instruments. Journal of Endodontics. 1999 Jun 1;25(6):427-30.

Bürklein S, Tsotsis P, Schäfer E. Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation. Journal of endodontics. 2013 Apr 1;39(4):501-4.

Li SH, Lu Y, Song D, Zhou X, Zheng QH, Gao Y, Huang DM. Occurrence of dentinal microcracks in severely curved root canals with ProTaper universal, WaveOne, and ProTaper next file systems. Journal of endodontics. 2015 Nov 1;41(11):1875-9.

Dane A, Capar ID, Arslan H, Akçay M, Uysal B. Effect of different torque settings on crack formation in root dentin. Journal of endodontics. 2016 Feb 1;42(2):304-6.

Shemesh H, Bier CA, Wu MK, Tanomaru‐Filho M, Wesselink PR. The effects of canal preparation and filling on the incidence of dentinal defects. International endodontic journal. 2009 Mar;42(3):208-13.

Hieawy A, Haapasalo M, Zhou H, Wang ZJ, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments. Journal of endodontics. 2015 Jul 1;41(7):1134-8.

De-Deus G, Silva EJ, Marins J, Souza E, de Almeida Neves A, Belladonna FG, Alves H, Lopes RT, Versiani MA. Lack of causal relationship between dentinal microcracks and root canal preparation with reciprocation systems. Journal of Endodontics. 2014 Sep 1;40(9):1447-50.

Li ML, Liao WL, Cai HX. A micro-computed tomographic evaluation of dentinal microcrack alterations during root canal preparation using single‑file Ni‑Ti systems. Experimental and therapeutic medicine. 2018 Jan 1;15(1):494-9.

Harandi A, Mirzaeerad S, Mehrabani M, Mahmoudi E, Bijani A. Incidence of dentinal crack after root canal preparation by ProTaper universal, Neolix and SafeSider systems. Iranian endodontic journal. 2017;12(4):432.

Ashraf F, Shankarappa P, Misra A, Sawhney A, Sridevi N, Singh A. A stereomicroscopic evaluation of dentinal cracks at different instrumentation lengths by using different rotary files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study. Scientifica. 2016;2016.

Karataş E, Gündüz HA, Kırıcı DÖ, Arslan H. Incidence of dentinal cracks after root canal preparation with ProTaper Gold, Profile Vortex, F360, Reciproc and ProTaper Universal instruments. International endodontic journal. 2016 Sep;49(9):905-10.

Neto F, Ginjeira A. Comparative analysis of simulated root canals shaping, using ProTaper Universal, Next and Gold. Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial. 2016 Apr 1;57(2):82-6.

Pereira ES, Peixoto IF, Viana AC, Oliveira II, Gonzalez BM, Buono VT, Bahia MG. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments. International endodontic journal. 2012 May;45(5):469-74.

Shen Y, Zhou HM, Zheng YF, Campbell L, Peng B, Haapasalo M. Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments. Journal of endodontics. 2011 Nov 1;37(11):1566-71.

Das S, Pradhan PK, Lata S, Sinha SP. Comparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM. Journal of conservative dentistry: JCD. 2018 Mar;21(2):153

Uygun AD, Kol E, Topcu MK, Seckin F, Ersoy I, Tanriver M. Variations in cyclic fatigue resistance among ProTaper Gold, ProTaper Next and ProTaper Universal instruments at different levels. International endodontic journal. 2016 May;49(5):494-9.

Shantiaee Y, Dianat O, Mosayebi G, Namdari M, Tordik P. Effect of Root Canal Preparation Techniques on Crack Formation in Root Dentin. Journal of endodontics. 2019 Apr 1;45(4):447-52.

El Nasr HM, El Kader KG. Dentinal damage and fracture resistance of oval roots prepared with single-file systems using

different kinematics. Journal of endodontics. 2014 Jun 1; 40(6):849-51.

KuMaRi MR, KRiShnaSwaMy MM. Comparative analysis of crack propagation in roots with hand and rotary instrumentation of the root canal-An ex-vivo study. Journal of clinical and diagnostic research: JCDR. 2016 Jul;10(7):ZC16.

Liu R, Kaiwar A, Shemesh H, Wesselink PR, Hou B, Wu MK. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Journal of endodontics. 2013 Jan 1;39(1):129-32.

Capar ID, Arslan H, Akcay M, Uysal B. Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin. Journal of endodontics. 2014 Sep 1;40(9):1482-4.

Rahman H, Chandra A, Singh S. In vitro evaluation of dentinal microcrack formation during root canal preparations by different NiTi systems. Indian J Restor Dent. 2014;3:43–7

Versluis A, Messer HH, Pintado MR. Changes in compaction stress distributions in roots resulting from canal preparation. International Endodontic Journal. 2006 Dec;39(12):931-9.

Adorno CG, Yoshioka T, Suda H. The effect of root preparation technique and instrumentation length on the development of apical root cracks. Journal of endodontics. 2009 Mar 1;35(3):389-92.


Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.

An Initiative of The Tamil Nadu Dr MGR Medical University